FiFix OTMr K
FiFix OTMr K (galvanized steel wire sheath)
Application
Benefits
Structure
Сharacteristics
- For broadband access networks construction
- Intended for laying in the cable sewerage, pipes, blocks, collectors, on bridges and overhead roads.
- Direct burial in soils of all the categories, including in areas with high corrosion aggressiveness and the territories infected with rodents, except the soils exposed to frost and other deformations.
- High performance specifications
- Easy cable installation
1. singlemode optical fiber, freely laid in central tube, filled with thixotropic hydrophobic gel
2. steel wire sheath
3. binding lapping
4. polyethylene protective hose
MU number, max. pcs. | 1...24 |
Cable diameter, mm | (7,2...9,5) +/- 0,5 |
Cable weight, kg/km | 91…122 |
Maximum tensile force (short-term), kN | 4...7 |
Minimum bending radius, mm | 20 x cable diameters |
Allowable crushing strength, not more than, N/mm | 3 000 |
Operation temperature range, ° С | – 10°С - +60°С |
Storage temperature range, ° С | – 10°С - +60°С |
Installation temperature range, ° С | 0°С - +60°С |
Construction length, km | 2, 00 |
Cable type | Price, USD/km at the rate of the NBU | ||
---|---|---|---|
before 5 km | 5 - 20 km | 20 - 40 km |